Security Affairs
Google fixes the eighth actively exploited Chrome zero-day of 2026|Iris Ohyama data breach may expose personal information of 7.7 million people|France Blames Iran for the Supermarket Fridge Attacks|QNAP Warns Users as Plex2Shell Flaws Are Used to Hack NAS Devices|CISA and the FBI Warn Of Attacks against Industrial Refrigeration Controllers|Fake GitHub Security Tools Infect Over 2,000 PCs With Malware|The BBC has a plan for a Black Sky event, and it runs on FM radio|Don’t Hand Propaganda a Gift: Reading the Brenner Base Tunnel SE Breach Calmly|SECURITY AFFAIRS AI-CYBERSECURITY NEWSLETTER ROUND 7|SECURITY AFFAIRS MALWARE NEWSLETTER ROUND 122|Security Affairs newsletter Round 603 by Pierluigi Paganini – INTERNATIONAL EDITION|Attackers Exploit Third-Party Provider to Raid French Bank Crédit Mutuel Arkéa|Google fixes the eighth actively exploited Chrome zero-day of 2026|Iris Ohyama data breach may expose personal information of 7.7 million people|France Blames Iran for the Supermarket Fridge Attacks|QNAP Warns Users as Plex2Shell Flaws Are Used to Hack NAS Devices|CISA and the FBI Warn Of Attacks against Industrial Refrigeration Controllers|Fake GitHub Security Tools Infect Over 2,000 PCs With Malware|The BBC has a plan for a Black Sky event, and it runs on FM radio|Don’t Hand Propaganda a Gift: Reading the Brenner Base Tunnel SE Breach Calmly|SECURITY AFFAIRS AI-CYBERSECURITY NEWSLETTER ROUND 7|SECURITY AFFAIRS MALWARE NEWSLETTER ROUND 122|Security Affairs newsletter Round 603 by Pierluigi Paganini – INTERNATIONAL EDITION|Attackers Exploit Third-Party Provider to Raid French Bank Crédit Mutuel Arkéa|
Advertisement

Ad Placeholder

Full Width × 90

Breaking News

Nexpose appliances were shipped with a weak default SSH configuration

Security experts at Rapid7 have discovered a security issue in the SSH configuration for its Nexpose appliances tracked as CVE-2017-5243. Owners of Nexpose appliances have to apply an update to their systems to fix the issue in the default SSH configuration. The devices were shipped with an SSH configuration that allowed obsolete algorithms to be […]

Nexpose appliances

Security experts at Rapid7 have discovered a security issue in the SSH configuration for its Nexpose appliances tracked as CVE-2017-5243.

Owners of Nexpose appliances have to apply an update to their systems to fix the issue in the default SSH configuration.

The devices were shipped with an SSH configuration that allowed obsolete algorithms to be used for key exchange and other functions.

Nexpose appliances

The Nexpose appliances were allowing to used weak and out of date encryption algorithms such as AES192-CBC, Blowfish-CBC, and 3DES-CBC, and KEX algorithms such as diffie-hellman-group-exchange-sha1.

“Because these algorithms are enabled, attacks involving authentication to the hardware appliances are more likely to succeed. ” states the advisory published by Rapid7.

“This vulnerability is classified as CWE-327 (Use of a Broken or Risky Cryptographic Algorithm). Given that the SSH connection to the physical appliances uses the ‘administrator’ account, which does have sudo access on the appliance, the CVSS base score for this issue is 8.5.” 

Nexpose devices designed to help users analyze vulnerabilities and reduce the surface of attack. The issue affects all the Nexpose appliances, owners with root access can fix the problem by editing /etc/ssh/sshd_config file in the appliance to ensure only modern ciphers, key exchange, and MAC algorithms are accepted.

After updating the configuration file, users need to verify that the changes have been correctly applied. Any missing part of the configuration may trigger a syntax error on service restart with consequent loss of connectivity.

“You can run this command and compare the three output lines with the configuration block above:

  1. egrep “KexAlgorithms|Ciphers|MACs” /etc/ssh/sshd_config

“After verifying the configuration change, restart the SSH service by running “service ssh restart”. Once that completes, verify you can still connect via ssh client to the appliance in a separate terminal. Do not close the original terminal until you’ve successfully connected with a second terminal.” states the advisory.

“This change should not impact connections from Nexpose instances to the physical appliance. The main impact is shoring up access by SSH clients such that they cannot connect to the appliance using obsolete algorithms,” Huckins wrote.

The vulnerability could have let an attacker in a privileges position on the network to force an algorithm downgrade between an SSH client and the Nexpose appliance during the authentication phase.

In order to mitigate the issue, it is possible to remove server-side support for the out of date encryption algorithms.

[adrotate banner=”9″]

Pierluigi Paganini

(Security Affairs – hacking, Nexpose appliances)

[adrotate banner=”13″]